ASHRAE STANDARD 55-2010 PDF

ASHRAE STANDARD 55-2010 PDF

ANSI/ASHRAE Standard Thermal Environmental Conditions for Human Occupancy is an .. ANSI/ASHRAE Standard Standard references ( Appendix H) Provides a list of references in the version of the standard, with direct. ANSI/ASHRAE Standard (Supersedes ANSI/ASHRAE Standard ). Includes ANSI/ASHRAE addenda listed in Appendix |. o) ASHRAE. ANSI/ASHRAE Standard 3. It is intended that all of the criteria in this standard be applied together since comfort in the indoor environment is.

Author: Kigakora Diktilar
Country: Zambia
Language: English (Spanish)
Genre: Politics
Published (Last): 1 April 2011
Pages: 102
PDF File Size: 15.14 Mb
ePub File Size: 15.96 Mb
ISBN: 433-9-95317-356-4
Downloads: 20511
Price: Free* [*Free Regsitration Required]
Uploader: Tojagar

To evaluate the thermal comfort over a period of time in a mechanically conditioned space, the exceedance hours are the sum of all the hours when the absolute value of PMV is greater than 0. SinceStandard 55 has been rewritten with a renewed focus on application of the standard by 555-2010 and use of clear, enforceable language. First, one can estimate the clothing insulation from the table provided in section five. All of the building systems must be designed to maintain the occupied spaces at the indoor conditions specified by one of the described evaluation methods at design conditions.

Radiant temperature asymmetry between ceiling and floor, and air and walls 555-2010 be limited to reduce discomfort.

ASHRAE 55 – Wikipedia

This chart represents only two variables, dry-bulb temperature and relative humidity. Retrieved 5 December Relative humidity Humidity ratio w Dew point Wet bulb Vapor pressure. For satisfaction surveys, the thermal satisfaction scale shall end with choices: When the number is under 20, at least 16 must reply for the survey to sandard the survey representative.

The body of the standard consists of a foreword describing changes made in the current versioneight sections and two normative appendices:. For occupant-controlled naturally conditioned spaces, the measured results shall be check with the comfort zone established by adaptive model.

It was revised in,and This page was last edited on 12 Septemberat For mechanically conditioned spaces, the PMV-based comfort zone has to 552-010 determined, which includes measuring and recording the stabdard activity and clothing insulation. A occupant-controlled naturally conditioned space is where the thermal conditions of the etandard are primarily regulated by occupant-controlled openings.

  AJA HD10DA PDF

One can also take into account the posture of the occupants. And this equation is only valid when the metabolic rate is between 1.

The section sets provisions for increasing the upper air temperature limit at elevated air speeds asrae 0. In the standard underwent significant changes with the addition of two thermal comfort models: The applicability of the cooling effect of air movement was expanded to apply to naturally conditioned spaces.

Thus, it only provides an approximation of the clothing insulation value of a moving person.

Standard 55 – Thermal Environmental Conditions for Human Occupancy

Given the widespread and easy accessibility of computing power and third-party implementations of the analytical method, it is expected that more users will favor the comprehensive analytical methods over the graphical method. Clothing insulation refers to the heat transfer of the entire body, which includes the uncovered parts, such as hands and stanndard.

In the body of the standard was rewritten in mandatory language, with informative language moved from the body of the standard to informative appendices. The graph is valid for prevailing mean temperatures between 10— Clothing insulation is the resistance to sensible heat transfer provided by a clothing ensemble expressed in units of clo, which is a standzrd to quantify the insulation provided by garments and clothing ensembles.

As standatd rates increase over 1. Compliance is achieved if the conditions provide thermal neutrality, measured as falling between This section of the standard is applicable for the design of buildings.

Both of these sections are clarified and streamlined for use by owners and third-party rating systems. You can also still use the operative temperature button, yet each point will have the same MRT. Metabolic rate is the rate of transformation of chemical energy into heat and mechanical work by metabolic activities of an individual, per unit of skin surface are expressed in units of met equal to Section 7 underwent major revisions for measuring thermal comfort in existing spaces including procedures for physical measurements and survey methods, and how to evaluate and report results.

Standard 55 specifies conditions for acceptable thermal environments and is intended for use in design, operation, and commissioning of buildings and other occupied spaces. Accurate data from the measurement using thermal manikins is acceptable.

  GAZ1 THE GRAND DUCHY OF KARAMEIKOS PDF

If the clothing ensemble in question reasonably matches the clothing ensemble in the table, the indicated value can be used. By using this site, you agree to the Terms of Use and Privacy Policy.

This table can be used together with the previous one, so that one can add or subtract the clothing ensemble from the clo value of each garment. Method is applicable only for occupant-controlled naturally conditioned spaces that meet all of the following criteria: Considering that a sleeping person or one in reclining posture will be provided with sufficient insulation with the bedding material, and he or she is also free to adjust, it is impossible to determine the clothing insulation effect for these occupants unless they are immobile.

So far, all the clothing insulation value can be used when the occupant is standing. Exceedance hour is the number of occupied hours within a defined time period in which the environmental conditions in an occupied space are outside the comfort zone. One has to keep in mind that the results from point-in-time surveys are only effective during the time when the surveys were solicited.

There should be at least seven points on the scale ending with “very acceptable” and “very unacceptable. For a mechanically conditioned space at an instance in stnadard, the PMV and SET model shall be used to establish the comfort zone, and the local thermal discomfort shall be evaluated against the limit posed this standard as well.

Standard 55 – Thermal Environmental Conditions for Human Occupancy

There is a figure in the section five of the standard which predicts the representative clothing insulation of the occupants as a function of the average outdoor air temperature at From Wikipedia, the free encyclopedia.

To cite this webpage: For occupant-controlled naturally conditioned space, the adaptive model shall be used to determine the thermal comfort boundaries. This is the energy produced from a unit skin surface area of an average person seated at rest.